Diagnostics Coverage Range (Dc) Of The Motor Controller; Areas Of Application And Approval By Authorities - Festo CMMO-ST Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
CMMO-ST Safe torque off
1.2.3

Diagnostics coverage range (DC) of the motor controller

The diagnostics coverage range of the motor controller depends on the type of diagnostics applied. If a
potentially dangerous malfunction is recognised during the diagnostics, appropriate measures must be
taken to maintain the safety level.
Note
The CMMO-ST cannot detect a cross circuit in the input circuit by itself.
• Check to see if a cross-circuit detection of the input circuit and the connection wiring
is required for your application.
• If necessary, use a safety switching device with cross-circuit detection for activation
of the safety module.
1.2.4

Areas of application and approval by authorities

The motor controller carries the CE mark. Standards and test values, which the product must comply
with and fulfil, can be found in the section "Technical data"
chap. 5. The product-relevant EC directive can be found in the declaration of conformity.
Certificates and the declaration of conformity for this product can be found at
www.festo.com
Certain configurations of the product have been certified by Underwriters Laboratories Inc. (UL) for the
USA and Canada. These configurations bear the following mark:
Note
Observe the following if the UL requirements are to be complied with in your applica-
tion:
– Rules for observing the UL certification can be found in the separate UL special
documentation. The technical data stated therein take priority.
– The technical data in this documentation may show values deviating from this.
26
UL Listing Mark for Canada and the United States
Festo – CMMO-ST Safe torque off – 1210a English

Publicité

Table des Matières
loading

Table des Matières