8. Specifications
Input voltage range
Current draw, normal operation
Current draw, low cell voltage
Load Disconnect output
Charge Disconnect output
VE.Bus communication port
Operating temperature
Humidity
Protection grade
Material and color
Weight
Dimensions (hxwxd)
Standards: Safety
Emission
Immunity
Automotive Directive
10
9 – 70 VDC
10 mA (excluding Load Disconnect current)
2 mA
Normally high (output voltage ≈ supply voltage – 1 V)
Floating when load needs to be disconnected
Source current limit: 2 A
Sink current: 0 A
Normally high, (output voltage ≈ supply voltage – 1 V)
Floating when charger should be disconnected
Source current limit: 10 mA
Sink current: 0 A
GENERAL
Two RJ45 sockets to connect to all VE.Bus products
-20 to +50°C
Max. 95% (non condensing)
IP20
ENCLOSURE
ABS, matt black
0,1 kg
105 x 78 x 32 mm
STANDARDS
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN61000-6-1, EN 55014-2
EN 50498
°
0 - 120°F