1.2.d. ELECTRICAL AND PNEUMATIC CONNECTIONS
A good earth connection is essential for correct operation of the machine.
The electric connection used must be suit-
ably sized:
• to the electric power absorbed by the
machine, indicated on its data plate (Fig. 1);
• to the distance between the operating machine
and the power supply connection point, to ensure
that the voltage drop under full load does not
exceed 4% (10% during start-up) of the rated
voltage value specified on the plate
- The user must:
• fit a power plug in compliance with current regulations
on the power supply lead;
• connect the machine to its own electrical connec-
tion - A, Fig. 2 - equipped with a differential automatic
circuit breaker with 30mA sensitivity;
• install protection fuses on the power line that are
suitably sized in accordance with the indications
provided on the machine data plate (Fig.1);
• connect the machine to an industrial socket; the
machine must not be connected to domestic sockets.
Make sure that the available pressure and performance
of the compressed air system are compatible with what
is necessary for correct machine operation - see the
section "Technical data". For the correct operation of
the machine, the pneumatic supply line must provide a
pressure range from a minimum of 8 bar to a maximum
of 16 bar.
For correct equipment operation, the air produced must be suitably treated (not
above 5/4/4 according to standard ISO 8573-1).
User's manual
WARNING
Mod.
V
A
kW
Hz
Ph
bar/psi
WARNING
ANNO DI COSTRUZIONE /
Code
MANUFACTURED
X-XXXXXXXX/XX - XX
Serial N.
XXXXXXXXX
B
EN
1
A
2
75

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Teco-36tph

Table des Matières