Adjusting Scrub Head; Disc Brush Scrub Head; Cylindrical Brush Scrub Head - Tennant 5400 Opérateur Manuel Et Liste Des Piéces

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Recovery
Tank
Hose
Solution
Tank
Hose
FIG. 35
3. Flush out recovery tank with clean water.
NOTE: The water must not be hotter than 60
(140
F) or tank damage may occur. Do not use steam
_
to clean tank.
4. If you operated the ES option, you must drain
solution tank also. Flush out solution tank with
clean water.
5. Replace drain hose cap(s) securely.
6. When finished scrubbing, perform the Daily
Maintenance procedures (See MACHINE
MAINTENANCE).

ADJUSTING SCRUB HEAD

DISC BRUSH SCRUB HEAD

NOTE: Before adjusting scrub head, check tire
pressure and fill solution tank.
1. With pads/brushes installed, lower scrub head to
floor and apply maximum pad pressure.
2. Turn off machine and remove key.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
and set parking brake, if equipped.
3. From center front and back of scrub head,
measure distance from top edge of scrub head to
floor (Figure 36).
Tennant 5400
(04- -05)
C
_
Home Find... Go To..
FIG. 36
4. If scrub head is not level, loosen lock nut and turn
scrub head leveling screw to level, 1 inch wrench
required. Tighten down lock nut once head is level
(Figure 37).
FIG. 37

CYLINDRICAL BRUSH SCRUB HEAD

To check for proper brush adjustment perform the
following steps:
NOTE: Before checking or adjusting scrub brush,
check tire pressure and fill solution tank.
1. Apply a powdered substance, such as chalk, on a
smooth, level floor.
2. With scrub head raised, position scrub head over
test area and set parking brake, if equipped.
3. Lower scrub head to floor with minimal down
pressure.
4. Turn solution switch to the off position.
5. Turn speed control knob to slowest setting and
slightly rotate control grips forward for 2 seconds
while holding machine in one spot.
OPERATION