OPERATION
DRAINING ANTIFREEZE AFTER STORING
1. Remove the concentrate line from the storage
plug and install the quick--disconnect fitting,
supplied with kit, into the inlet line of the
concentrate pump.
2. Drain as much of the excess RV antifreeze as
possible. If the antifreeze does not flow out of the
line, squeeze and release the inlet hose several
times.
3. Install the FaST--PAK into its holder. Remove the
kit fitting from the concentrate line and connect the
concentrate line to the FaST--PAK. If the
concentrate does not flow into the line, simply
squeeze and release the inlet hose several times.
4. Run the machine in the FaST mode for 5 minutes
before adding water to the solution tank. Add
water to the solution tank and the machine is now
ready for service. It may be several minutes until
the FaST system is back to the optimum operating
condition.