Error display

In order to provide an immediate diagnosis for any errors that may occur, the following errors
can be determined via on-screen error codes.
Error code
Error
E 100 Temperature sensor paused
E 101 Temperature sensor short circuit
E 103 Interruption bench sensor
E 104 Short-circuit bench sensor
E 111 Humidity sensor paused
E 211 Excess temperature fuse paused
E 510 Lack of water – refi ll period
E 511 Lack of water – refi ll period exceeded
For each error code the
warning icon on the screen starts to fl ash so that it is easy to
see that there is an error code.
To quit after notifi cation of a lack of water (error message E511) press the Mode button and
then immediately restart the device.

Other error options that are not displayed and their causes:

KScreen is blank – no background lighting
Check the main switch setting.
Check the mains connection! Each of the 3 phases L1, L2 and L3 must have 230V AC.
Check the fuses!
The temperature can not be set to over 70°C
Check whether the device is in Finnish mode. („P3=0")