The control unit switch (Switch-
off)
The control unit switch can be found on the
top end of the unit. Using this switch, you
can isolate the electronics from the mains
supply in case of a breakdown.
In case of breakdown, press the control unit
switch on the left part of the rocker to the
fi rst position (switch position 0). The unit is
now completely switched off.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).
Changing the heating time limitation for commercial use
Attention! Completely disconnect the control unit from the electrical circuit!
As a standard, the control unit is supplied with a heating time limitation of 6 hours.
A jumper is present in the middle of the lower circuit board for conversion to 12 hours. It is
inserted at the „6h" mark at the factory. The heating time can be set to 12 or
moving it to the „12h" or „24h" mark. If the jumper is removed completely the maximum
heating time is 6 hours.
The maximum heating time for private use is 6 hours. Resetting to 12 or more
hours is permissible only for supervised (commercial) operation.