Connecting the vaporizer
To connect the vaporizer, use silicon con-
necting lines 4 x 1,5 mm2 as well.
Warning: When connecting the
vaporizer make sure it is correctly
attached to the water bath (WB) and low
water shutoff (WM). If you switch these con-
nections, you disable the water defi ciency
function and bypass the thermostat. As a
result, the vaporizer will overheat.
This is a fi re hazard!!
Illust. 6 shows the circuit diagram. The con-
trol unit can detect water defi cit if there is a
zero-potential feed at the WM-input.
WbWm N
TB
3 kW
vaporizer
Warning: Always connect
the neutral conductor of the
sauna oven. During steam operation,
one phase of the oven is shut down;
therefore the heating load is no lon-
ger symmetrical. The result is that
the neutral wire is no longer current-
free.
44
Connectors in
the control unit
Illust. 6
Fitting of the humidity sensor
onal)
1.
The humidity sensor is fi tted in the
centre of the sidewall facing away from
the oven at a height of approximately
150 cm.
2. See illust. 12 for the connection se-
quence of the strands.
3. Ensure the connection is exactly correct-
incorrect connections can lead to defects
in the sensor.
H u m i d i t y
sensor
The sensors are connected to the clamps at
the lower right outer edge of the control unit
in accordance with the following scheme.
TEMP.-Sensor
TEMP.-
H-Sensor
Nr. 2
Nr. 1
Limiter Ub E G
Programmed maximum values
EN 60335-2-53:2003
rH [%]
100
90
80
70
60
50
40
30
20
10
0
10
20
30
GB
1 2 3 4
Illust. 12
Ofenfühler/Sensor
Feuchtefühler
humidity sensor
Ub G E
T [°C]
40
50
60
70
80
90
100
(opti-
142˚C