Electrical connection

The electrical connection
only be done by a qualifi ed elec-
trical technician under authority of the
regulations of the local power supply
company and those of the VDE.
GIn general, there can only be one per-
manent connection to the power supply
network, to include a device which allows
the unit to be disconnected from the power
source with a contact distance of at least 3
mm from all terminals.
All electrical installations and connector
cables inside the cabin must be able to
withstand temperatures up to 170°C. Ple-
ase use the table below to determine the
required cable diameters for this task.
Attach the power supply lead wire as shown
in Illust. 5 to the power supply terminals of
the control unit. Connection instructions
are printed directly in the control unit.
Power supply
lead wire
Air intake opening
Capacity
Electrical.
acc. DIN
Connection
4,5 kW
3N AC
6,0 kW
50 Hz
7,5 kW
400 V
9,0 kW
All cross sections of a line are minimum diameters in mm² (Copper line)
42
may
Lead wire for cabin
lighting
Illust. 5
Fuse control
For cabin size
unit in A
3 x 16

Connecting the sauna oven

Assemble the sauna oven according to the
instructions provided by the manufacturer
in front of the air intake opening.
Lead the silicon lines through the electrical
conduits to their respective terminals on the
control unit and connect them according to
the circuit diagram printed there.
Please note: If no electrical conduits are
present, drill a hole with a diameter of 10
mm next to the air intake opening and lead
the oven control cables through this hole
to their corresponding terminals (U V W) in
the control unit. To protect the silicon lines
from external infl uences, install them in a
shielded fashion. For this task, use a fi tting
cable or simple PVC conduit and lead the
silicon cable through it to the control unit.

Connecting the sauna lamp

The sauna lamp must be splashproof (by
Standard IPx4) and resistant to ambi-
ent temperature. The sauna lamp can be
mounted anywhere except in the area of
the rising hot air above the oven.
Connecting
cable main
- control unit
in mm²
4 - 6 m³
6 - 10 m³
5 x 2,5
8 - 12 m³
10 - 14 m³
GB
Connecting
cable control
unit - heater
in mm²
5 x 1,5