III - Initial startup and time setting
■ To return to the factory configuration short-circuit during several seconds (with a screwdriver
for example) the 2 pins located on the back of the clock above the label «Factory Config»
while the clock is operating.
■ To position the hands at noon short-circuit the same 2 pins when powering on the clock
(when connecting the PoE network cable).
The sweep second movement start by advancing his second hand for 10 seconds and stops to
wait for NTP synchronization.
Once the movement is synchronized, the hands move to one of the following positions: 4:00.00
or 8:00.00 or 12:00.00.
After 3 minutes the hands set themselves to the NTP time.
Indoor: HM/HMS Standard movement (ex: Profil 940)
Indoor: Sweep second movement (ex: Profil 930)
Outdoor: HMS Standard movement
■ The default configuration is as follows (this configuration is listed on the back of the device)
- IP configuration by DHCP
- Time zone: EUR
■ The full factory configuration is as follows
- Clock name: "BODET-@MAC"
- Time zone: EUR
- Synchronisation address: 239.192.54.1
- Trap type: V2C
- Pool period for unicast synchronisation: 15 min.
- Temperature alarm threshold: –5°C to +55°C (indoor) and -20°C to +55°C (outdoor).
■ LEDs status
- Yellow LED: network type (ON=100M, OFF=10M).
- Green LED: network activity + power.
The clock sets itself to 12:00 after 48 hours without synchronization.
22
Pins to be short-circuited
Pins to be short-circuited
Pins to be short-circuited
- Multicast synchronisation
- Synchronisation address: 239.192.54.1
- IP configuration by DHCP
- Multicast synchronisation
- SNMP disabled
- Trap status sending interval: 24H
- No password
EN