→ Connect the silencer to the free exhaust port 2.
For usage in an aggressive environment, we recommend
using a pneumatic hose to drain all free pneumatic ports
in a neutral atmosphere.
Control function I:
→ Connect control medium to pilot air port 1 and 2 of the
actuator (see "Fig. 7")
Pressure on pilot air port 1 opens the valve.
Pressure on pilot air port 2 closes the valve.
Exhaust port
CFA, CFB
pilot air port
CFI
Pilot air port
CFA, CFB, CFI
Fig. 7:
Ports
Pilot air hose:
Pilot air hoses of sizes 6/4 mm or ¼" can be used.
Optionally a pilot air port via G⅛" thread is possible.
Type 2101
Start-up
2
1
8
START-UP
8.1
Safety instructions
WARNING!
Risk of injury due to improper installation!
▶ Only trained technicians may perform installations.
▶ Perform installations using suitable tools only.
Risk of injury due to unintentional activation of the system
and uncontrolled restart.
▶ Secure equipment against unintentional activation.
▶ Ensure that the system starts up in a controlled manner only.
8.2
Pilot pressure
WARNING!
For control function I – risk of pilot pressure failure.
The valve stays in an undefined position in the event of a pilot
pressure failure.
▶ To ensure a controlled restart of the device, apply pilot pressure
and activate the medium.
Risk of injury due to moving parts.
▶ Do not reach into openings in the device.
→ Set the pilot pressure according to the type label information,
chapter "5" and flow direction (chapter „8.3").
English
15