Control Unit - Burkert 8690 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type 8690 Ex
Disassembly
13.2. Disassembly the pneumatic
control unit
procedure:
1. Pneumatic connection
DangEr!
risk of injury from high pressure!
• Before dismounting lines and valves, turn off the pressure and
vent the lines.
Loosen the pneumatic connection.
Series 20xx:
Loosen the pneumatic connection between Pneumatic Control
Unit and actuator.
2. Electrical connection
DangEr!
risk of electric shock!
• Before reaching into the system, switch off the power supply
and secure to prevent reactivation!
• Observe applicable accident prevention and safety regulations
for electrical equipment!
Circular plug-in connector:
Loosen the circular connector.
Cable gland:
Open the Pneumatic Control Unit: unscrewing the transparent
cap in an anticlockwise direction.
Unscrew the screw terminals and pull out cables.
3. Mechanical connection
Loosen the fastening screws.
Remove the Pneumatic Control Unit upwards.
Transparent cap
Pneumatic

Control Unit

Cable gland
Fastening screws
Pneumatic
connections
Actuator
Pneumatic con-
nection to the
Series 20xx
Fig. 23: Disassembly the Pneumatic Control Unit
english
(2x)
actuator
Series 21xx
31

Publicité

Table des Matières
loading

Table des Matières