2. How to use
Value Description
Operation without load shedding
0
relay, factory setting
Operation with normal
1
load shedding relay
Operation with sensitive
2
load shedding relay
Brightness: Reduce the display brightness e.g. to safe energy. The brightness can be
set separately for operation screen and standby screen.
• Operation screen 5-100%
• Standby screen 0-100% (0% = display OFF)
The setting of the standby screen will be activated after one minute in standby mode.
Icon Size: Selection of "S" small or "L" large visualization The displays and symbols in
the main control are then displayed accordingly either smaller or larger.
Sound: Activate / deactivate operating sounds.
Note: Alarm signals and instruction sounds are not affected by this function.
Load Shedding: If further three-phase appliances are connected, a load shedding relay
designed for electronic instantaneous water heaters (CLAGE no. 82250) can be con-
nected to phase conductor L2. This relay ensures the operation of the water heater by
switching off other consumers until the end of heating operation.
Tap on or to set a value of 0, 1 or 2.
Operating mode 1 must be selected first, thus to check the correct operation of the
load shedding relay at low appliance output (35 degree celsius setpoint and low water
flow rate). Mode 2 must be selected if the load shedding relay flickers.
Flow Limit: Setting of flow rate limitation.
Setting options:
"OFF"
no flow rate limitation (motor valve deactivated)
"AUTO"
automatic adjustment, i.e. flow rate is limited in a way so that the selected
outlet temperature is reached
"ECO"
flow rate limitation to max. 8.0 l/min
e.g. "9.0" limitation to a freely selectable value between 4.5 and 25 l/min
Note: If the Eco function has been activated in the menu "Savings", the flow is
automatically set to "ECO". Changing the flow to a higher value than 8 l/min
deactivates the Eco function
Factory Settings: All factory settings can be recalled:
Note: All customised user profiles, and power and water prices entered, are
deleted. If a load shedding relay is connected, the correct value must be reset
under "Load shedding".
Delete Statistics: Use this function to delete all previously collected statistical data.
Deleted statistical data cannot be restored.
Thermal treatment: With this function, you can support a thermal treatment of your
appliance and the following pipeline, including the tap. A thermal disinfection accord-
ing to the accepted rules of technology is not replaced.
• Tap OK to start the treatment cycle and the outlet temperature is set to 70 °C. The
function is disabled if the appliance is connected to a shower.
• Draw hot water for at least three minutes to heat the pipes to the tap completely.
• A change of the temperature or 30 sec without water flow terminates the treatment
cycle.
• The number as well as the accumulated duration and the water amount of all ther-
mal treatments will be saved and can be viewed under "Device information".
21