11. Malfunctions - causes and remedies

Display
-0-
_____
-----
Err 05
Err 06
Err 07
LO
If the errors are not corrected or if error messages not listed here are displayed, please contact the
Soehnle Industrial Solutions customer service.
52
Description
The scale automatically resets to
zero when switched on.
If the scale is outside the inten-
ded tolerance range, the display
shows -0-.
Underload: Only the lower hori-
zontal lines appear in the display
field.
Overload: The display field only
shows the upper
Horizontal lines. The maximum
weighing range has been excee-
ded.
Zeroing limit exceeded or not
reached.
Taring is not possible when the
scale is unloaded or overloaded.
Printing not possible in case of
under- or overload.
When the battery symbol is lit
continuously:
scale is in battery mode.
When the battery symbol flashes:
Batteries are discharged. Approx.
30 minutes of operating time
remain.
Battery is empty.
Remedy
Unload the scale.
Remove any dirt.
If the scale does not display zero after
a few seconds, please contact your
manufacturer's service department.
Switch off the scale and switch it on
again. The zero point is reset automati-
cally.
If the weight of the person to be weig-
hed exceeds the maximum capacity of
the scale, weighing with this model is
not possible.
Check whether there are any objects
on the scale. Remove them and restart
the scale.
Load the scale in the normal range.
Load the scale in the normal range.
No error.
Connect device to mains adapter (opti-
onally available) or change batteries.
Connect device to mains adapter (opti-
onally available) or change batteries.