9 Switching on
Make sure that the unit and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
During normal operation the surface of the
illuminator can reach high temperatures.
Do not allow direct contact and position
the appliance where it is inaccessible to
unauthorised persons. Before touching
switch off the illuminator and allow to cool
for a minimum period of 10 minutes.
Do not stay in the vicinity of the device
when it is powered. Act on the device only
in the absence of a power supply.
MNVCUPT3_1511_EN
Make sure that all parts are fastened down
firmly and safely.
The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
between 60 and 105 minutes, depending
on conditions.
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.
31