• Install the rubber washer and the plastic nut on the threaded end of
the cell. Tighten plastic nut firmly.
• Place the cell vertically with the cap end down into a plastic 19 liters
(5 U.S. gallons) bucket and carefully pour the acid solution into the
cell until the 4 plates are covered (careful not to overflow). The acid
solution will begin to produce bubbles to clean the electrodes.
A foaming action will follow, which is caused by the scale deposits
being dissolved from the plates. If rigorous foaming action does not
begin, the cell does not need to be cleaned. Rinse and reinstall the
cell.
• Allow the electrodes to remain in the solution until the foaming
has stopped. However, DO NOT leave in acid for more than fifteen
minutes. Excessive acid cleaning will damage the electrolytic cell.
• Pour the acid solution back into the bucket and rinse the cell
thoroughly with clean tap water. If deposits are still visible, repeat
operation for fifteen minutes maximum (some acid may need to be
added to the solution).
• Remove the plastic nut and washer from the cell and keep them for
future cell cleaning.
• Rinse the in.clear with fresh water.
• Re-install the in.clear unit into spa system plumbing, tighten all
connections by hand. Open the spa flow Shut Off Valves.
• Reconnect the keypad and power cable.
• Turn power on and start up the pump. Check the keypad to see that
the bromine generation LED is on and resume normal operation.