in.clear
™
Blinking "AC "
A blinking "AC" message
displayed on the keypad indicates
that there is a problem with the
power input. The most common
reason is that the in.clear unit is
supplied with 120 VAC instead of
240 VAC. Please make sure power
cord is connected properly to a
.
240 VAC source
Bromine Generation
indicator blinking
A blinking Bromine Generation
LED means that the system is
unable to generate bromine
because no water flow is
detected by the in.clear system.
This situation is normal if the
pump is not running and no
water is flowing through the
in.clear. However, if water
is circulating through the
in.clear unit, and the Bromine
Generation LED is still blinking,
make sure that the in.clear is
installed on the pressure side
of the pump and that water is
properly flowing through the
in.clear unit.
Bromine Generation
indicator is off
The Bromine Generation LED
indicator is OFF when there is no
need for bromine generation.
This situation is normal, especially
with low maintenance level of
bromine generation set on the
keypad.
troubleshooting
In.clear is turned off
The OFF message indicates that
the in.clear in turned Off.
Press Boost key
to reactivate
the in.clear.