Gecko Aeware in.clear Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

getting started
4 - Adding
Sodium Bromide (such as BromiCharge)
Metric Calculation:
Add 0,143 Kg of sodium bromide 98% active ingredient, such as
BromiCharge per 100 liters of water to attain 1 400 ppm TDS value
(Total Dissolved Solids).
Example, if your spa holds 1200 liters of water, add 1,72 Kg of sodium
bromide (12 X 0,143 Kg).
Imperial Calculation:
Add sodium bromide which has a guarantee of at least a 98% active
ingredient, such as BromiCharge per100 US gallons of water.
Example, if your spa holds 300 US gallons of water, add 3.6 lbs of
sodium bromide (3 X 1.2Lb).
Note: Your spa manufacturer can tell you how much water your spa
holds (in liters or gallons).
5 - Activating the system:
Power up your spa and activate the system by pressing the Boost key
20
: (continued)
6 - Determining the proper Maintenance Level for my spa
(refer to page 24 for details)
Determining the proper maintenance level for your spa is an extremely
important step. DO NOT use your spa during this step as it will slow the
process. Be patient. Make sure you follow steps 1 through 6 previously
described before performing the following steps.
Your maintenance value was set at the factory. It should read 15 to start.
Since the in.clear bromine generation is not an instantaneous process,
at least 24 hours should be allowed for the bromine bank to reach
stabilization. After that period, check bromine level to make sure it is
back between 3-5 PPM.
If the bromine level is within that range, you are ready to use your spa.
If the bromine level is above 5 PPM, decrease the maintenance level.
If the bromine level is below 3 PPM, increase the maintenance level.
Always allow at least 24 hours for the bromine bank to stabilize. Repeat
these steps until you are able to stabilize your bromine level between 3
and 5 PPM.
.
Do NOT increase/decrease maintenance level in steps greater
than 2.
Setting the maintenance level to a value that's too high can cause
damage to your equipment.
Check bromine level and always test water before entering
in.clear

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Aeware in.clear 0605-500002

Table des Matières