Troubleshooting - Gecko Aeware in.clear Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

troubleshooting

Low Sodium Bromide Error
Low sodium bromide Error
(Err) occurs when the sodium
bromide level is too low. The lo
LED indicator will blink when
the error is present. The in.clear
system will not generate bromine
until the Low Sodium Bromide
Error (Err) is cleared.
To clear the Low Sodium
Bromide Error (Err), add sodium
bromide (such as BromiCharge)
to the spa water. Let water
circulate for 5 minutes. Activate
diagnostic mode and add more
sodium bromide until gauge
is back in the green zone. Exit
diagnostic mode.
28
Low Sodium Bromide
Warning
Low Sodium Bromide Warning
(Lo) indicates the need to add
sodium bromide (such as
BromiCharge) to the spa water.
In Diagnostic Mode, add sodium
bromide to the water until the
gauge reaches the green zone
to clear a Low Sodium Bromide
Warning (Lo).
If after adding sodium
bromide the Low Sodium
Bromide Warning (Lo) or Low
Sodium Bromide Error (Err) still
occurs it could be the result of:
• calcification of the electrolytic
plates;
• airlocks trapped in the in.clear
unit or insufficient flow;
• internal pressure switch
problem.
in.clear
High Sodium Bromide
Warning
High Sodium Bromide Warning
(Hi) occurs when too much
sodium bromide (such as
BromiCharge) is present in the
water or there is a high TDS level
(hardness, alkalinity, organic
compounds, ...).
To clear a High Sodium Bromide
Warning, readjust the sodium
bromide content of your water
in Diagnostic Mode, into green
zone by draining some water
from your spa and adding fresh
water.