in.clear
BromiCharge gauge (LEDs)
In Diagnostic mode, the BromiCharge gauge (LEDs) indicates the
approximate sodium bromide level of your spa water.
When adding sodium bromide (such asBromiCharge), the gauge
indicator will gradually shift to the right. When adding clean water to
the spa the indicator will shift to the left. In order to achieve the proper
level, start pumps and add 454 Grams (1 Pound) at a time and always
allow 5 minutes for the gauge to react before adding more sodium
bromide (such as BromiCharge).
The green zone in the center area of the gauge and a 12.0 value should
be targeted for optimal performance.
BromiCharge gauge
BromiCharge level monitoring
Water must be circulating
through the in.clear cell in order
for the Diagnostic Mode to work.
If no water is circulating through
the in.clear unit, a FLO message
will appear on the keypad display.
Make sure the pump is circulating
water through the in.clear.
Be aware that the gauge
will move according to sodium
bromide level. Make sure your
water temperature is at least 32° C
(90° F).