cell cleaning

Cell cleaning:
In.clear includes a self-cleaning feature to prevent scale deposits on the
graphite electrodes of the in.clear system. However, deposits may still
form due to hard water. If that happens the cell should be cleaned in
an acidic solution
.
To clean the in.clear cell, follow these steps:
All power must be disconnected before any service procedure is
performed. Disconnect the communication cable and power
cable of the in.clear unit.
34
Refer to acid manufacturer's instructions.
Wear eye protection and rubber gloves during these
operations. Splashing or spilling acid can cause severe
personal injuries and/or property damage.
Always work in a well-ventilated area.
Always add acid to the water; never add water to the acid.
Phosphoric acid
or muriatic acid
Do not pour acid outside of the unit where
the connectors are located.
Never use Acetic acid to clean the cell, as this will cause
permanent damage to cell components and void the
warranty.
• To remove scales from the cell, we recommend using Phosphoric
acid (non-diluted) as the preferred cleaning product.
• Close the spa Flow Shut Off Valves. Unscrew both unions
from the unit and remove the cell from the spa equipment
compartment.
in.clear