How to view isolated or inhibited inputs with operating mode "0"

The presence of one or more isolated or inhibited inputs is indicated by the specific LED on the keypad and by the reader LED.
An input can only be isolated if it has been programmed as such.
An input may be manually isolated by Master / User / Installer / Technical Manager code.
To view isolated or inhibited input addresses you can proceed in two ways:
In this case the isolated or inhibited inputs viewed are those which have at least one partition in common with the keypad being
operated and the valid code to be entered.
To view addresses of isolated inputs:
1) Press the MENU key and then press
2) Press
, on the display appears
3) Enter <Master / User / Installer / Technical Manager code>, press
4) Press
. The inputs are identified as "<Logical address>:<Name>" on the second line. For
example, an input to which the kitchen detector is connected with logical address "3" and named
"Kitchen" will be identified as "In003:Kitchen".
5) Use
and
to scroll the list of open inputs.
6) Press
and
to see the input customisation.
7) Press
repeatedly to exit from the menu after examining the list.
Entering a valid code: in this case the isolated or inhibited inputs viewed are those which have at least one partition in common with the
keypad being operated and the valid code entered.
1) Enter <Master / User / Installer / Technical Manager code>, press
repeatedly until ISOLATED INPUTS appears.
2) Press
. The inputs are identified as "<Logical address>:<Name>" on the second line. For
example, an input to which the kitchen detector is connected with logical address "3" and named
"Kitchen" will be identified as "In003:Kitchen".
3) Use
and
to scroll the list of open inputs.
4) Press
and
to see the input customisation.
5) Press
repeatedly to exit from the menu after examining the list.
repeatedly until ISOLATED INPUTS appears.
MP500/4N-8-16
.
twice and then press
SYSTEM STATUS
ISOLATED INPUTS
ENTER CODE
ISOLATED INPUTS
READ LIST
ISOLATED INPUTS
In003: Kitchen
MP500/16
12/01/2014 10:10
ISOLATED INPUTS
In001:...
MP500/16
12/01/2014 10:10