Control Screen 2 (Temperature Setting); Control Screen 3 (Engine Speed Setting); Control Screen 4 (Lighting - Optional); Control Screen 5 (Transfer Pump - Optional) - Dibo JMB-M 500/30 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E N
    F U N C T I O N I N G
6

Control Screen 2 (Temperature setting)

In this screen you can set the desired burner temperature. Move the control
stick upwards (raise temperature) or downwards (lower temperature) to set the
desired temperature. Increase/decrease can be done in steps of 5 °C.
Minimum value 0 °C - Maximum set point: depending on the factory setting.
Operate to the left: return to the main screen (at each other screen, same
principle). Operate to the right: navigate to the next operation menu (at each
other screen, same principle)..
7

Control Screen 3 (Engine speed setting)

In this screen you can set the desired engine speed.
The basic setting at the start is set at 50%.
Pay attention: If the key contact is put into position
"ON" , the engine speed is not adjustable.
Start the key contact by before the engine speed is adjustable! Move the control
stick upwards (increase speed) or downwards (lower speed) below to set the
desired engine speed. Increase/decrease in steps of 10%.
Minimum value 0% - maximum value 100%.
8

Control Screen 4 (Lighting - optional)

In this screen you can set the lighting. Move the control stick upwards (work
light on/off) or downwards (beacon light on/off) to set the desired condition.
Push the control stick to activate, push again to deactivate.
9

Control Screen 5 (Transfer pump - optional)

In this screen you can turn on / off the filling pump.
Move the control stick upwards (turn on) or downwards (turn off)..
10

Message screens

A message screen can appear when for example service is necessary / flame
DiBO 28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1.780.123

Table des Matières