Translation of the original instructions
BATTERY REPLACEMENT :
1
Product
Battery
GYSPACK PRO
6FM-22
To replace the battery :
•
The booster must be disconnected form the power supply.
•
First the back panel must be unscrewed (14 screws) and removed.
•
Once the back panel is removed, the battery front appears (cf illustration). The battery is connected to the GYSPACK
PRO at two points : at the - terminal - 1 and at the + terminal 2 . To remove the battery, remove the 2 screws
that enable the connection between the battery and the GYSPACK PRO at the terminals + and -.
When putting a new battery, make sure to observe the polarities of both the battery and
the GYSPACK PRO. Terminal - on the left, terminal + on the right (cf illustration). Put the 2
screws and washers back, tighten the nuts (recommended torque wrench 4 N.m).
•
Place the booster's backpanel screws back on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSPACK PRO
Type
Voltage (V)
Lead- acid battery
12
Capacity (Ah)
Dimensions (cm)
22
34 x 20 x43
EN
2
Battery ref
53151
13