Acronyms And Abbreviations - Whirlpool WEG730H0DS0 Fiche Technique

À l'usage du technicien de réparation uniquement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR SERVICE TECHNICIAN'S USE ONLY
IPC: Induction Power Control Board
IPS: Induction Power System
NTC: Negative Temperature Coefficient
A
If all the lights on the User Interface are Off and there is no response
from the cooktop, complete the following steps:
1.
Unplug range or disconnect power.
2.
Check the continuity of the fuses on the EMI board. If one
or more of the fuses is blown, replace with a new fuse.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
Check that it is working. If it is not, go to Step 6.
6.
Unplug range or disconnect power.
7.
Change the Induction Power System (IPS).
8.
Replace all parts and panels before operating.
9.
Plug in range or reconnect power.
10. Check that it is working. If it is not, go to Step 11.
11. Unplug range or disconnect power.
12. Change the User Interface.
13. Replace all parts and panels before operating.
14. Plug in range or reconnect power.
INDUCTION COOKTOPS ONLY

Acronyms and Abbreviations

Failure/Error Codes
UI: User Interface Board
EMI: Filter Board (Electromagnetic Interference)
B
If all lights on the User Interface are Off and the User Interface is making
a beeping noise, this indicates there is a stuck key on the User Interface.
Complete the following steps:
1.
Unplug range or disconnect power.
2.
Open the cooktop and inspect User Interface for any damage.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
If the issue is still there, disconnect power and continue to Step 6.
6.
Replace User Interface.
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
16

Publicité

Table des Matières
loading

Table des Matières