FOR SERVICE TECHNICIAN'S USE ONLY
To check for proper voltage, complete the following steps:
1.
Unplug range or disconnect power.
2.
Connect voltage measurement equipment.
FROM
Door switch
P7-4
Main cavity oven temp
P10-4
sensor
Drawer oven temp
P10-1
sensor
Oven light
P5-4
Component Testing Chart
RESISTANCE: MEASURE
TO
WITHOUT POWER APPLIED
P7-5
Door open = open circuit
Door closed = closed circuit
P10-3
1000 - 1200Ω at room
temperature.
Measure only resistance, not
voltage.
The operating temperature
range is from -40°F (-40°C) to
1100°F (593°C).
P10-2
1000 - 1200Ω at room
temperature.
Measure only resistance, not
voltage.
The operating temperature
range is from -40°F (-40°C) to
1100°F (593°C).
W (Neutral) P6-3
0 - 40Ω nominal.
14
3.
Plug in range or reconnect power and confirm voltage reading.
4.
Unplug range or disconnect power after performing voltage
measurements.
NOTES
Disconnect connector P10 from control
before measuring RTD.
Disconnect connector P10 from control
before measuring RTD.
NOMINAL
VOLTAGE
5 VDC
NA
NA
120 VAC