FOR SERVICE TECHNICIAN'S USE ONLY
To check for proper voltage, complete the following steps:
1.
Unplug range or disconnect power.
2.
Connect voltage measurement equipment.
Location On the Cooktop
EMI filter board
Induction Power Control (IPC): Left and right
Induction Power Control (IPC) to blower fan: Left and right
Induction Power Control (IPC) to the element sensor: Left and right
Induction Power Control (IPC) to the User Interface
Component Testing Chart
3.
Plug in range or reconnect power and confirm voltage reading.
4.
Unplug range or disconnect power after performing voltage
measurements.
Checkpoints
J1 - BR - BU
J1 - BR - BU
J205 - (BK) - (R)
J205 - (BK) - (BU)
J604 - (1) - (2)
J605 - (1) - (2)
J806 - BK - 1
J806 - LT BU - 2
J806 - W - 3
J806 - R - 4
J806 - Y - 5
22
Results Voltage
From 208VAC to 240 VAC - 60Hz
From 208VAC to 240 VAC - 60Hz
From 0VDC to 12VDC
+5VDC
0V
+10.5V
+5VDC
WIDE_DATA
Ground
Standby
+10VDC