Whirlpool WEG730H0DS0 Fiche Technique page 17

À l'usage du technicien de réparation uniquement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

There are 3 types of failures associated with the cooktop. The description of these failures and the impact they will have on the rest of the cooktop are listed
in the following.
Failure – Type 1
Failure type 1 comes from the Induction Power Control (IPC). This failure will affect only one burner. The user may continue to use the other burners.
Failure – Type 2
Failure type 2 usually comes from the Induction Power Control (IPC) (there could be some exceptions). These failures affect all burners associated
with that Induction Power Control (IPC); the user may continue to use the burners that belong to the other Induction Power Control (IPC).
Failure – Type 3
Failure type 3 comes from the User Interface. This failure disables the entire cooktop. When this type of failure occurs, all the burners are switched OFF
by the User Interface.
Service Code
Failure Description
Shown on Display
F-12
Coil under current
Type of
Repair Suggestions
Failure
Type 1
1.
Unplug range or disconnect power.
2.
Check for the correct connections at T2A - T2B or T3A - T3B on the Induction Power
Control (IPC) (whichever connection the burner is plugged into). If connections are
correct, go to Step 3.
3.
Replace the burner coil.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power.
6.
Check for proper operation.
7.
If everything operates, end service. If error code still appears, disconnect power and
go to Step 8.
8.
Replace the Induction Power System (IPS).
9.
Replace all parts and panels before operating.
10. Plug in range or reconnect power.
17

Publicité

Table des Matières
loading