CODE
WHAT IS IT?
F3E2 Drawer Sensor Open or Shorted
Drawer temperature reading greater than 995°F
(535°C) or less than 0°F (-18°C).
P10-1
WH/BU
WH
P10-2
WH
Oven Control
MRC2
WHEN CAN IT OCCUR?
Within 20 seconds of
activating a cook or
clean function.
Drawer Temp Sensor
WH
WH
RECOMMENDED CORRECTIVE ACTION PROCEDURE
1.
Unplug range or disconnect power.
2.
Inspect control board connector P10 for a backed out terminal
or loose connection. If found, reconnect or replace harness
and go to Step 10. If not, go to Step 3.
3.
Disconnect control board connector P10. Measure resistance
across P10-1 and P10-2. At room temperature, the thermal
sensor should read between 1000Ω and 1200Ω . Reconnect
P10. If test results are good, go to Step 4. If test results are
not correct, go to Step 9.
4.
Replace all parts and panels before operating.
5.
Plug in range or reconnect power
6.
Enter a cook function (i.e., Bake). If the error code doesn't
reappear after 20 seconds, go to Step 13. If the error code
reappears, go to Step 7.
7.
Unplug range or disconnect power.
8.
Replace main control and go to Step 10.
9.
Inspect connection at drawer thermal sensor. Disconnect and
measure resistance across thermal sensor terminals. At room
temperature, the thermal sensor should read between 1000Ω
and 1200Ω . If resistance measured out of range, replace
thermal sensor. If resistance measured within range, replace
harness.
10. Replace all parts and panels before operating.
11. Plug in range or reconnect power
12. Enter a cook function (i.e., Bake) and verify the error code
doesn't reappear after 20 seconds.
13. Verify operation is normal. Enter the diagnostic mode to view
the "Faults" screen. Press START TIME or DELAY START to
clear each Fault code(s).
9