Service Code
Failure Description
Shown on Display
F-47
Power supply from Induction
Power Control (IPC) to User
Interface is missing or WIDE
communication error between UI
and Induction Power Control (IPC)
or an open fuse on the filter board
Type of
Repair Suggestions
Failure
Type 2
1.
Unplug range or disconnect power.
2.
Check that the cables between the User Interface and the Induction Power Control
(IPC) are not damaged and are firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check that it is working. If it is not working,
disconnect power and replace the cables between the User Interface and the
Induction Power Control (IPC).
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power and check that it is working. If it is not working,
go to Step 7.
7.
Unplug range or disconnect power.
8.
Check the continuity of the fuses on the EMI board. If either of the fuses is blown,
replace with a new one.
9.
Replace all parts and panels before operating.
10. Plug in range or reconnect power and check that it is working. If it is not working,
go to Step 11.
11. Unplug range or disconnect power.
12. Change the Induction Power System (IPS).
13. Replace all parts and panels before operating.
14. Plug in range or reconnect power. Check that it is working. If it is not working,
go to Step 15.
15. Unplug range or disconnect power.
16. Change the User Interface.
17. Replace all parts and panels before operating.
18. Plug in range or reconnect power.