À l'usage du technicien de réparation uniquement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Service Code
Failure Description
Shown on Display
F-40
Induction Power System (IPS)
failure
F-42
Power supply
F-43
Under voltage
Type of
Repair Suggestions
Failure
1.
Type 1
Unplug range or disconnect power.
or
2.
Check that the cable between the User Interface and the Induction
Type 2
Power Control (IPC) is not damaged and is firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
Verify if error is still present. If yes, disconnect power.
6.
Replace the Induction Power System (IPS).
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
Type 2
1.
Check for 240 volts AC at the main incoming power supply connection
by completing the following steps.
2.
Unplug range or disconnect power.
3.
Connect voltage measurement equipment.
4.
Plug in range or reconnect power and check for 240 volts at J1 L to N, and then J2
L to N at the EMI filter board, and then J1 L to N at both Induction Power Controls
(IPCs). If voltage is correct, disconnect power, replace the Induction Power System
(IPS), and go to Step 5. If voltage is not correct, disconnect power and check for
an open fuse on the EMI filter board. If there is not an open fuse, have a qualified
electrician check the home power supply.
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power.
Type 2
1.
Unplug range or disconnect power.
2.
Check the AC voltage with a multimeter.
3.
Is the voltage above 196 volts? If the AC voltage is below 196 volts,
then this failure is caused by abnormal supply voltage.
4.
If the voltage is above 196 volts, then replace the Induction Power System (IPS).
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power.
19