FOR SERVICE TECHNICIAN'S USE ONLY
Service Code
Failure Description
Shown on Display
F-21
Supply power frequency
F-25
Stuck fan on Induction Power
System (IPS) (Right or left side
fan, depending on which side of
the display the failure is on.)
F-36, F-37
Temperature sensor is not
working
Type of
Repair Suggestions
Failure
Type 2
1.
Unplug range or disconnect power.
2.
Replace the Induction Power System (IPS).
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
If the issue is not fixed, contact a qualified electrician to verify the frequency of the
home power supply is 60 Hz.
Type 2
1.
Unplug range or disconnect power.
2.
Check that the cooling fan connector is firmly plugged in.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
5.
If the issue is not fixed, disconnect power.
6.
Replace the cooling fan.
7.
Replace all parts and panels before operating.
8.
Reconnect the power.
9.
If the issue is not fixed, disconnect power.
10. Replace the Induction Power System (IPS).
11. Replace all parts and panels before operating.
12. Plug in range or reconnect power.
Type 1
1.
Unplug range or disconnect power.
2.
Check that the temperature sensor is between 184kΩ and 292kΩ at room
temperature and is firmly plugged in. If the sensor is not between 184kΩ and 292kΩ,
replace the coil and go to Step 5. If the sensor is between 184kΩ and 292kΩ and the
electrical connection is good, go to Step 3.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check that the coil is working. If it is not
working, disconnect power and replace the non-working coil and the Induction
Power System (IPS).
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power.
18