Service Code
Failure Description
Shown on Display
F-56
Wrong or invalid configuration
F-58
Wrong or invalid configuration
F-60
UI does not work
C-81, C-82
Over temperature
C-83
Temperature sensor stuck
Type of
Repair Suggestions
Failure
1.
Type 3
Unplug range or disconnect power.
2.
Replace the User Interface.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
Type 2
1.
Unplug range or disconnect power.
2.
Replace the Induction Power System (IPS).
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power.
1.
Type 3
Unplug range or disconnect power.
2.
Check for loose connections between the User Interface and both Induction
Power Controls (IPCs).
3.
Replace the User Interface.
4.
Replace all parts and panels before operating.
5.
Reconnect the power.
Type 2
Not enough ventilation: Check the installation according to the Installation Instructions.
In particular, check the blower intakes.
Type 2
1.
Unplug range or disconnect power.
2.
Check to see if the temperature sensor that is causing the failure is firmly plugged
into the proper connector.
3.
Replace all parts and panels before operating.
4.
Plug in range or reconnect power and check to see if the coil is working. If it is not
working, unplug range or disconnect power and replace the coil that is causing the
failure with a new coil.
5.
Replace all parts and panels before operating.
6.
Plug in range or reconnect power and check to see if the coil is fixed. If it is not
working, disconnect power and replace the Induction Power System (IPS).
7.
Replace all parts and panels before operating.
8.
Plug in range or reconnect power.
21