High pressure and low pressure parts
Check the hoses, piping and connections on external damages and leaks.
If damaged or leaks these must be immediately replaced.
5
Spray equipment
Check lances and guns on leaks, external damages and hair cracks. If damaged
or leaks these must be immediately replaced. Check the spray image of the
water jet, if these blows out to much you must replace the nozzle. Check
protective cap-nozzle on damages and replace if necessary. Check the thread
of the couplings on external damages. At damage let these replace without
delay.
6
Electrical part
Checks visible electric wiring and components (among other things switches)
on external visible damages. If damaged let replace the concerning parts.
7
Burner
Check if the burner opening is clear of pollution. Checks pipes and connections
on leaks and external damages. Check the filter and replace if necessary. Check
the sort fuel and the pollution in the tank and clean if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected.
The switching on of the ignition transformer without the ignition pins
are connected, are not permitted.
We recommend during maintenance activities certainly checking
the connections of the ignition cables and for the case the
burner would not work, certainly don't let run the burner.
8
Water tank
Check the water tank on external damages and leaks.
Check when the tank is filling if the float system works properly.
9
Engine
Check the engine for loose parts, leaks. Check the oil level with the oil gauge.
When the oil level has gone down too much, or contamination of the oil is
found, this must be replaced before continuing the works. Check that the intake
opening is not blocked. Check the filter for extreme contamination and clean /
replace it if necessary. Check the filter for contamination and clean / replace it if
necessary.
10
Fuel tank
Check for damage or leakages. If damaged, you have to replace/repair the tank.
Regularly check the tank on contamination.
11
Battery
Check the battery on good connections / possible wear and whether the battery
needs to be recharged. If the idling battery voltage drops below: 12.6 V (or if
stored / not used during 6 months), this must be recharged. This can happen by
means of a trickle charger, standard charger or workhouse charger. Reloading
need to be done by a qualified technician.
Caution: Ventilate sufficiently when reloading battery, avoid risk of sparks (no
smoking), care for a good electrical connection of the charger & the battery!
12
Purging the softener pump (option)
The softener hose pump does not need to be purged.
Regularly clean the vent cap, remove product residues!