Cleaning Extractor Tray - Miller Filtair 550H Manuel D'utilisation

Table des Matières

Publicité

5-2. Cleaning Extractor Tray

OM-254 498 Page 19
!
Do not operate unit without
extractor tray.
!
Do not breathe the particles
collected by the fume extrac-
tor. Wear approved safety
equipment
gloves, long sleeve shirt)
when servicing filter and
spark guard. Dispose of
used element and collected
particles according to local,
state, and federal require-
ments.
!
Read and understand the
Material Safety Data Sheets
(MSDSs) and the manufac-
turer's instructions for met-
als, consumables, coatings,
cleaners, and degreasers.
!
Use lifting aid or two persons
to remove extractor tray.
Particle tray is heavy when
full.
.
See Section 4-1 for installation
hardware torque values.
1
Extractor Tray
Remove hardware securing tray to
extractor side brackets and tray
side mounting bracket.
1
Lower tray from hood. Clean out
debris from tray.
Reinstall and secure tray to side
brackets
Vacuum top of hood.
Tools Needed:
1/2 in.
(respirator,
300 965-7 / 300 965-10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtair 550hwFiltair 750sFiltair 750swFiltair 1100hw

Table des Matières