8.2 Free-standing submerged installation on ring
stand
Fig. 5
Free-standing submerged installation on a ring stand
Pumps for free-standing submerged installation can stand freely
on the bottom of the tank. The pump must be installed on a ring
stand. See fig. 5.
The ring stand is available as an accessory.
In order to facilitate service on the pump, fit a flexible union or
coupling to the elbow on the discharge port for easy separation.
If a hose is used, make sure that the hose does not buckle and
that the inside diameter of the hose matches that of the pump
discharge port.
If a rigid pipe is used, fit the union or coupling, non-return valve
and isolating valve in the order mentioned, when viewed from the
pump.
If the pump is installed in muddy conditions or on uneven ground,
support the pump on bricks or a similar support.
Proceed as follows:
1. Fit a 90 ° elbow to the pump discharge port and connect the
discharge pipe/hose.
2. Lower the pump into the liquid by means of a chain secured to
the lifting bracket of the pump. We recommend that you place
the pump on a plane, solid foundation. Make sure that the
pump is hanging from the chain and not the cable. Make sure
that the pump is standing securely.
3. Hang up the end of the chain on a suitable hook at the top of
the tank and in such a way that the chain cannot come into
contact with the pump housing.
4. Adjust the length of the motor cable by coiling it up on a relief
fitting to ensure that the cable is not damaged during
operation. Fasten the relief fitting to a suitable hook at the top
of the tank. Make sure that the cable is not sharply bent or
pinched.
5. Connect the motor cable.
The free end of the cable must not be submerged,
Note
Note
as water may penetrate into the cable.
12

8.3 Torques for suction and discharge flanges

Grade 4.6 (5) galvanized steel screws and nuts
Pitch
Nominal
circle
diameter
Screws
diameter
[inch]
[inch]
2 1/2
5 1/2
4 x M16
3
6
8 x M16
4
7 1/2
8 x M16
6
9 1/2
8 x M20
2 1/2
5 1/2
4 x 5/8" UNC
3
6
8 x 5/8" UNC
4
7 1/2
8 x 5/8" UNC
6
9 1/2
8 x 3/4" UNC
Grade A2.50 (AISI 304) steel screws and nuts
Pitch
Nominal
circle
diameter
Screws
diamete
[inch]
[inch]
2 1/2
5 1/2
4 x M16
3
6
8 x M16
4
7 1/2
8 x M16
6
9 1/2
8 x M20
2 1/2
5 1/2
4 x 5/8" UNC
3
6
8 x 5/8" UNC
4
7 1/2
8 x 5/8" UNC
6
9 1/2
8 x 3/4 UNC
The gasket must be a full face, reinforced paper
Caution
gasket like Klingersil C4300. If softer gasket
material is used, torques must be reconsidered.
Specified tightening
torques rounded off
by +/- 5
[ft.lbs (Nm)]
Slightly
Well
oiled
lubricated
50 (70)
45 (60)
50 (70)
45 (60)
50 (70)
45 (60)
100
90 (120)
(140)
50 (70)
45 (60)
50 (70)
45 (60)
50 (70)
45 (60)
90 (120)
80 (100)
Specified tightening
torques rounded off
by +/- 5
[ft.lbs (Nm)]
Slightly
Well
oiled
lubricated
-
45 (60)
-
45(60)
-
45 (60)
-
90 (120)
-
45 (60)
-
45(60)
-
45(60)
-
80 (100)