Cardin Elettronica SL Série Mode D'emploi page 73

Masquer les pouces Voir aussi pour SL Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 90
• Press the arrow keys
- status
means that the function TA-TC or TL will activate at the chosen time and will remain active
1
until it is deactivated by a new event;
means that the function TA-TC or TL will be deactivated at the selected time;
- status
0
• Press PROG/OK to confirm the function and return to the set events menu.
• Choose another event to set or press
In the example on the right
EVENT 0
Event programming example:
Let's assume that we have a factory which opens at 08:00 in the morning and closes at 18:00 in the
evening from Monday to Friday. On Saturday instead it opens at 08:30 and closes at 12:30.
To allow access to our employees' vehicles we want the main gate to open automatically at 07:50,
remain open for 20 minutes and then to close at 08:10.
• Set the date and time (parameters 8a and 8b) and enable Automatic Reclosing (parameter 5b ON):
- with
highlighted, press 'PROG/OK' twice to access the sub menu;
SET EVENTS
highlighted, press 'PROG/OK', set the time 07:50, select the opening command
- with
MO-FR
set the status to
TA
1
EVENT
INTERVAL
0
1
2
3
to choose between the status
to return to the
EXIT
the opening command
then set the other three events by following table below.
TIME
MO-FR
07:50
MO-FR
08:10
MO-FR
18:00
MO-FR
18:15
and
and vice versa:
0
1
menu.
CALENDAR
TA
will be given on Thursday at 08:50.
COMMAND
STATUS
TA
1 (ON)
TA
0 (OFF)
TA
1 (ON)
TA
0 (OFF)
73
EVENT 0
THU 08:50 TA 1
EVENT 1
(EMPTY)
EVENT 2
(EMPTY)
EVENT 0
MO-FR 07:50 TA 1
EVENT 1
MO-FR 08:10 TA 0
EVENT 2
(EMPTY)
EVENT 2
MO-FR 18:00 TA 1
EVENT 3
MO-FR 08:15 TA 0
EVENT 4
(EMPTY)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bl sérieHl sérieSli sérieBli série

Table des Matières