4m) Reset parameters
• To reset all parameters to their default values press the PROG/OK button.
• Press the
key to confirm the choice and reset the parameters.
• Press the
key to go back to the previous screen without changing the parameters.
• Press the
key again to move to the next parameter.
Attention: This command will reset all the parameters to their default values including work times and current
sensor settings therefore you will have to repeat the gate programming procedure (see page 76).
4n) Firmware version
• The display shows the current firmware version eg. SLX15/324 V1.1.
The firmware version varies according to the type of ECU (SL-BL-HL).
• Press the
key to move to the next parameter
• Press PROG/OK to return to the main menu.
.
EXIT
60
4m) Reset parameters
DIST.
FROM OPEN
5 STEPS
PA U S E T I M E
240 SEC.
RESET PARAMETERS
OK
* * * * * * * * * * * * * * * *
RESET THE
*
*
* PARAMETERS ? *
* * * * * * * * * * * * * * * *
EXIT
OK
4n) Firmware version
RESET PARAMETERS
OK
FIRMWARE VERSION
SLX/324 V1.1
EXIT