TERMINAL BOARD CONNECTIONS FOR THE SLX3024 - SLX1524 - SLX824 - SLi924 PROGRAMMERS
1-2 MOT motor power supply
3-4 ENCODER inputs Bl-Gr for the encoder signal
5-6 ENCODER inputs Gy-Yw for the encoder signal
7
LCK unlocking signal
8
CMN common for all inputs and outputs
9-10 LC-CH2 potential free contact for the activation of the courtesy light
(separate power supply Vmax=30 Vac/dc: Imax=1A) or the second
radio channel.
Selection is carried out through the digital display D1
11
CMN common for all inputs and outputs
LP - 24 Vdc 25 W output for warning lights flashing (50%),
12
12,5 W continuous activation
13
LS - 24 Vdc 3W output for an indicator light
CMN common for all inputs and outputs
14
15
24 Vdc controlled output, powering external loads
CMN common for all inputs and outputs
16
17
24 Vdc output, powering external loads
18
TA (N.O. contact) opening button input
TC (N.O. contact) closing button input
19
20
TAL (N.O. contact) limited opening button input
21
TD (N.O. contact) dynamic button input
CMN common for all inputs and outputs
22
23
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts
the cycle until a new movement command is given)
CP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke
24
a travel direction inversion (see 'ACT. SAFETY EDGE' page 89) during
the closing stage and during the opening stage.
25
FS (N.C./8.2 kΩ)
safety and control devices in input
(1)
(1)
(2)
(stop photocell). The
49
opening of this contact will block all movement, until the obstruction
has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled)
26
FI (N.C./8.2 kΩ) safety and control devices in input (photocells invert
the travel direction when an obstruction is detected).
Opening this contact will provoke a travel direction inversion during
closure due to the cutting in of the safety device
27
Outer conductor for radio receiver antenna
28
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω)
29
CMN common for the emergency buttons
30
EMRG1 (N.O. contact) emergency manoeuvring button input 1
EMRG2 (N.O. contact) emergency manoeuvring button input 1
31
(1)
Note
The total of the 2 external device outputs must not exceed 10W.
Note
(2)
The (N.C./8.2 kΩ) selection is carried out on the digital display D1.
ALL UNUSED NC CONTACTS MUST BE SHORT CIRCUITED
Consequently the corresponding security device tests (FI, FS) must also be
deactivated. If you want to activate the FI, FS test both the transmission
and receiver parts of the security devices must be connected to the binding
post marked (CTRL24Vdc). If the test is active there will be a 1 second delay
between the command transmission and movement of the gate.
• Switch on the power and make sure that the green power LED L1 is ON
and that the wrong battery connection LED L2 is OFF.
• If LED L1 doesn't light up check the condition of the fuses and the power
cable connection at the transformer primary.
• If LED L2 is ON disconnect the battery immediately.