5d) Warning lights
• Press PROG/OK to scroll between the available choices:
- FLASHING (use this setting for a 24V warning light without on-board electronics)
- FIXED (use this setting for a warning light with on-board electronics)
• Press the arrow button
choice and move to the next parameter.
This option determines the behaviour of the warning light output LP at binding post 12, 25 W output for warning lights
flashing 50%), 12,5 W continuous activation).
5e) Indicator light
• Press PROG/OK to scroll between the available choices:
- FLASHING - FIXED
• Press the arrow button
choice and move to the next parameter.
This option determines the behaviour of the indicator light output LS at binding post 13 (yield 3 W). Set to flashing
the indicator light flashes slowly during opening, rapidly during closing; remains lit when the gate is blocked but
not completely closed and is off when the gate is completely closed.
5f) Inverting photoelectric cells FI
• Press PROG/OK to scroll between the available choices:
- DURING CLOSING (FI is active only during closing)
- AND IN STOP (FI is also active when the gate is blocked: If the photocells are in alarm and the gate is
blocked, no movement commands will be accepted (even opening commands).
• Press the arrow button
save the choice and move to the next parameter.
In both cases activating the FI safety device during the closing stage will force travel direction inversion.
to confirm the choice eg. FLASHING. The programmer will save the
to confirm the choice eg. FLASHING. The programmer will save the
to confirm the choice eg. DURING CLOSING. The programmer will
62
5d) Warning lights
AUTO. RECLOSING
ON
PRE-FLASHING
ON
WARNING LIGHTS
FLASHING
5e) Indicator light
PRE-FLASHING
ON
WARNING LIGHTS
FLASHING
INDICATOR LIGHT
FLASHING
5f) Inverting photocells FI
WARNING LIGHTS
FLASHING
INDICATOR LIGHT
FLASHING
PHOTOCELL INVERT
DURING CLOSING