EXHAUST GAS VOLUME ADJUSTMENT (For Europe)
1
1
4. Simultaneously press and hold the "SELECT"
and "RESET" buttons, turn the main switch on,
and continue to press the buttons for 8 seconds
or more.
NOTE:
_
• All displays on the meter disappear except the
odometer/tripmeter/engine speed meter displays.
• "dIAG" appears on the odometer/tripmeter/engine
speed meter LCD.
5. Press the "SELECT" button to select the CO
adjustment mode "CO" 1 or the diagnostic
mode "dIAG".
6. After selecting "CO", simultaneously press the
"SELECT" and "RESET" buttons for 2 seconds
or more to activate the selection.
7. Press the "SELECT" and "RESET" buttons to
select a cylinder number 1.
NOTE:
The selected cylinder number appears on the
speedometer LCD.
8. After selecting the cylinder number, simulta-
neously press the "SELECT" and "RESET" but-
tons for 2 seconds or more to activate the
selection.
9. Change the CO adjustment volume 1 by press-
ing the "SELECT" and "RESET" buttons.
NOTE:
_
The CO adjustment volume appears on the odome-
1
ter/tripmeter/engine speed meter LCD.
• To decrease the CO adjustment volume, press
the "RESET" button.
• To increase the CO adjustment volume, press the
"SELECT" button.
10. Release the "RESET" and "SELECT" buttons to
activate the selection.
11. Turn the main switch to "off" to cancel the mode.
2-15
INSP
ADJ