Table 4-12 Machine data 1
Parameters
Row quantity
Row spacing
No. of holes
Pulses/100m
Blower target
Blower current
Spray width
Tr. track width
Headland –perm.PW
Sim. speed
Sim. speed
The total number of units is to be set here. This figure is required for the
operating width of the machine and for determining the tramline rhythm.
Distance between two adjacent units. This figure is required for
determining the tramline rhythm.
Number of holes in the sowing disc
Here the pulses / 100m are set for the speed sensor. If the value is
unknown, a calibration can be performed.
!
This value must be set very precisely, since it influences the speed,
the area measurement and the monitoring of the output quantity.
Here the blower speed, which should be monitored, is inputted. It is also
possible to save the current blower speed by using the
rotational speed deviates from the setpoint by more than ±10%, an alarm
is emitted.
Indication of the current blower speed
Working width of the plant protection spray, which is used for
maintaining crops. This figure is required for determining the tramline
rhythm.
Track width of tractor, with which plant protection measures are carried
out. This figure is required for determining the tramline rhythm.
With this setting it is possible to determine whether the permanent
deactivation of units at the end of the field is reversed again or not. With
the setting "off", the permanent deactivation is retained. If all units
should be used again, the deactivation must be reversed by using the
key.
Here the simulated speed can be activated and deactivated.
!
Caution: The simulated speed is retained until the job computer is
switched off or it is switched off again.
This speed is simulated if the simulated speed is activated.
30