Installation Of Control Panel - Tylo SENSE COMBI Notice D'installation

Masquer les pouces Voir aussi pour SENSE COMBI:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
6
10. Fit the spacers between heater and wall (to prevent the heater
from being lifted off) (see Figure 12, Page 6).
Figure 12: Fit spacers
11. Fit the cover for the water reservoir, herb grille and fragrance
holder/air humidifier (see Figure 13, Page 6).
Figure 13: Fitting the cover for the water reservoir, herb grille
and fragrance holder/air humidifier
12. Install the sensor on the wall see Figure 14, Page 6.
Tighten the screws carefully to avoid breaking the circuit
board.
Figure 14: Installing the sensor
Unusual voltages/numbers of phases
Before connecting to voltages or numbers of phases not listed in
the wiring diagram Figure 19, Page 8, contact Tylö Customer
Service.

Installation of control panel

The control panel can be installed inside or outside the sauna. If
installing it inside, the upper edge must not be more than 90 cm
from the floor. Use a type 2-LIFYCY 2X2X0.2 mm Twisted Pair
cable to connect control panel to heater.
To install the control panel:
1. Slacken the lock screw and split the panel and back piece
(see Figure 15, Page 6 pos 1).
1
Figure 15: Installing the control panel
1.
Slacken the lock screw
2.
Seal
3.
Mounting on wall
4.
Terminal
5.
Slide on the panel's glass element
6.
Tighten the lock screw
2. Glue the seal onto the back piece (see Figure 15, Page 6
pos 2).
3. Mount the back piece leaving sufficient room for electrical
cables to pass through their openings. Note that the hole for
the retaining screw must be at the bottom (see Figure 15,
Page 6 pos 3).
2
3
4
5
6

Publicité

Table des Matières
loading

Table des Matières