Figure 4: Sensor installation on ceiling on centreline of heater as
seen from the front and side
1.
200 mm
Positioning the heater - recess installation
To position the sauna heater in a recess:
1. Position the heater at a safe distance from the floor, side walls
and interior fittings (see Figure 5, Page 3).
2. Position the sensor according to the diagram (see Figure 5,
Page 3).
3
2
1
1
Figure 5: Positioning the heater - recess installation
1.
Minimum distance from side wall: 200 mm
2.
Sensor position: 200 mm from heater
3.
Sensor
4.
Max. 1000 mm
5.
Sensor position: 40 mm from ceiling, regardless of ceiling
height
6.
Minimum distance from ceiling: 1030 mm
7.
Minimum distance from interior fittings: 100 mm
8.
Minimum ceiling height: 1900 mm
9.
Minimum distance: 20 mm
10.
Minimum distance from interior fittings: 30 mm
11.
Distance from floor: 100-270 mm (with legs: 100 mm)
5
6
7
4
8
10
9
11
Positioning the control panel
The control panel must be correctly positioned with regard to
safety distances.
1
Figure 6: Safety distance, control panel
1.
Heater
2.
Control panel
3.
Max. 900 mm
4.
Min. 300 mm
Positioning the inlet vent
Install the inlet vent straight through the wall under the centreline
of the heater. Vent size for a family sauna approx. 125 cm².
The air circulation from the door must concord with the hot air cir-
culation from the heater.
3
4
2
3