BEFORE INSTALLATION
Parts
Check that the following parts are included in the packaging:
3
2
1
13
12
11
Figure 1: Sauna heater parts
1.
Sauna heater
2.
Herb bowl/air humidifier
3.
Herb bowl
4.
Brackets
5.
Sensor/temperature cut-out C-P, cable length 4 m
6.
Control panel
7.
Warning sticker in ten languages
8.
Cable between heater and control panel, 2-LIFYCY TP
2X2X0.2 mm² x 1
9.
Fragrance holder
10.
Sauna fragrance Lavender 10 ml x 1
11.
Spacers x 4
12.
Screws x 4
13.
Bracket screws x 2
14.
Connectors x 3
15.
Screws RXS/A2 PHIL B6x25 x 2 pcs
16.
Cable bushing Membrane 107-099 x 1
17.
Clips TC (5-7) x 10 pcs
Contact your dealer if anything is missing.
Installation requirements
For detailed instructions concerning sauna construction/ventila-
tion etc., go to: http://www.tylö.se/byggabastu and download this
document: "Building a sauna.pdf".
4
7
6
5
9
10
8
15
14
16
17
To ensure safe use of the heater, check that the following criteria
are met:
•
The sauna cabin should meet the requirements for ceiling
height and dimensions according to: "Building a sauna.pdf".
•
The sauna cabin should meet the requirements for insulation
and materials according to: "Building a sauna.pdf".
•
Cable (EKK) or electrical ducting for connecting the heater
must be run on the outside of the heat insulation.
•
Cable installation must be correctly performed (see The sec-
tion called Connection/wiring diagram, Page 8).
•
Fuse size (A) and power cable size (mm²) must be suitable
for the heater (see The section called Connection/wiring dia-
gram, Page 8).
•
The sauna ventilation must comply with the instructions in this
manual (see The section called Positioning the inlet vent,
Page 3, The section called Positioning the outlet vent,
Page 4).
•
The position of the sauna heater, control panel and sensors
must comply with the instructions in this manual.
•
The heater output (kW) must be suitable for the sauna volume
(m³) (see Table 1, Page 1). The minimum and maximum
volumes must not be exceeded.
NOTE! A brick wall without heat insulation increases
the warm-up time. Each square metre of plastered
ceiling or wall surface equals an additional 1.2–2 m³
of sauna volume.
Table 1: Output and sauna volume
Output kW
6,6
8
DANGER! Incorrect ventilation or heater positioning
!
can lead to the wooden panels drying out, posing a
fire risk in certain circumstances.
DANGER! Insufficient insulation of the sauna cabin
!
can pose a fire risk.
DANGER! Use of the wrong materials in the cabin,
!
such as chipboard, plasterboard etc., can pose a fire
risk.
DANGER! The heater must be connected by a qual-
!
ified electrician according to the applicable regula-
tions.
Sauna volume min./max. m³
4-8
6-12
1