BEFORE INSTALLATION

Parts

Check that the following parts are included in the packaging:
3
2
1
13
12
11
Figure 1: Sauna heater parts
1.
Sauna heater
2.
Herb bowl/air humidifier
3.
Herb bowl
4.
Brackets
5.
Sensor/temperature cut-out C-P, cable length 4 m
6.
Control panel
7.
Warning sticker in ten languages
8.
Cable between heater and control panel, 2-LIFYCY TP
2X2X0.2 mm² x 1
9.
Fragrance holder
10.
Sauna fragrance Lavender 10 ml x 1
11.
Spacers x 4
12.
Screws x 4
13.
Bracket screws x 2
14.
Connectors x 3
15.
Screws RXS/A2 PHIL B6x25 x 2 pcs
16.
Cable bushing Membrane 107-099 x 1
17.
Clips TC (5-7) x 10 pcs
Contact your dealer if anything is missing.

Installation requirements

For detailed instructions concerning sauna construction/ventila-
tion etc., go to: http://www.tylö.se/byggabastu and download this
document: "Building a sauna.pdf".
4
7
6
5
9
10
8
15
14
16
17
To ensure safe use of the heater, check that the following criteria
are met:
The sauna cabin should meet the requirements for ceiling
height and dimensions according to: "Building a sauna.pdf".
The sauna cabin should meet the requirements for insulation
and materials according to: "Building a sauna.pdf".
Cable (EKK) or electrical ducting for connecting the heater
must be run on the outside of the heat insulation.
Cable installation must be correctly performed (see The sec-
tion called Connection/wiring diagram, Page 8).
Fuse size (A) and power cable size (mm²) must be suitable
for the heater (see The section called Connection/wiring dia-
gram, Page 8).
The sauna ventilation must comply with the instructions in this
manual (see The section called Positioning the inlet vent,
Page 3, The section called Positioning the outlet vent,
Page 4).
The position of the sauna heater, control panel and sensors
must comply with the instructions in this manual.
The heater output (kW) must be suitable for the sauna volume
(m³) (see Table 1, Page 1). The minimum and maximum
volumes must not be exceeded.
NOTE! A brick wall without heat insulation increases
the warm-up time. Each square metre of plastered
ceiling or wall surface equals an additional 1.2–2 m³
of sauna volume.
Table 1: Output and sauna volume
Output kW
6,6
8
DANGER! Incorrect ventilation or heater positioning
!
can lead to the wooden panels drying out, posing a
fire risk in certain circumstances.
DANGER! Insufficient insulation of the sauna cabin
!
can pose a fire risk.
DANGER! Use of the wrong materials in the cabin,
!
such as chipboard, plasterboard etc., can pose a fire
risk.
DANGER! The heater must be connected by a qual-
!
ified electrician according to the applicable regula-
tions.
Sauna volume min./max. m³
4-8
6-12