Column tilting cylinder faulty.
• Replace column opening cylinder.
No air supply to cylinder.
• Hoses folded.
• Replace valve.
• Check tightness of arm pivot.
Faulty piston or gaskets.
• Replace pistons and gaskets.
Incorrect release valve setting.
• Adjust air delivery regulators on control valve.
Tyre pressure gauge needle fails to return to 0
Pressure gauge faulty or damaged.
• Replace pressure gauge.
Control out of operation.
• Check pedal board.
Rises slowly or has insufficient force.
• Check for folded hoses.
• Adjust delivery on pedal board.
• Replace the valve on the lifter pedal control board.
Cylinder leaking air.
• Replace cylinder gaskets.
• Replace cylinder.
WARNING
The "Spare parts" handbook does not authorize users to carry out work on the machine with the
exception of those operations expressly described in the user manual. It only enables users to
provide the technical assistance service with precise information in order to minimize delays.
AP1
Single / two-speed motor circuit board
M1
Motor
SQ1
Two-speed micro-switch
SQ2
Micro-switch (CLOCKWISE rotation)
SQ3
Micro-switch (ANTICLOCKWISE rotation)
XB1
Connector
Z1
Mains filter
User Manual TECO 100 Variant
Column does not tilt
Clamping arm cylinders leak air
Column tilts violently or too slowly
Wheel lifter not working