7.3 Floor protector

If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible
material as shown on figure 1.3 (see the dotted line area).
*Steel with a minimum thickness of 0.015" (0.38 mm) or ceramic tiles sealed together with
grout. No protection is required if the unit is installed on a non-combustible floor (ex.: concrete).
Note 1: The floor protection at the back of the stove is limited to the stove's required clearance
if such clearance is smaller than 8 inches (203 mm).
Note 2: Only required under the horizontal section of the connector. Must exceed each side of
the connector by at least 2 inches (51 mm).
30
Stove Builder International Inc. | 44826 | Rev: Aug 31 2018 3:17PM | Uncontrolled Copy
Clearances to combustible materials and floor protection
FLOOR PROTECTOR*
CANADA
G
8" (203 mm) – Note 1
H
8" (203 mm)
I
18" (457 mm)
From door opening
J
N/A (USA only)
M
8" (203 mm)
N
N/A (USA only)
USA
N/A (Canada only)
N/A (Canada only)
16" (406 mm)
From door opening
8" (203 mm)
N/A (Canada only)
Note 2