Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 9/6/2018 2:01:07 PM
Test report 103536746MTL-002 (11 of 21)
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103536746MTL-002
Date: 07/13/18
K
= Pitot Tube Constant, 34.97
P
or
= Pitot Tube Constant, 85.49
L
= Maximum acceptable leakage rate for either a pretest or post-test leak- check, equal
a
to 0.0003 m3/min (0.010 cfm) or 4 % of the average sampling rate, whichever is less.
L
= Leakage rate observed during the post-test leak-check, m3/min (cfm).
p
m
= mass of particulate from probe, mg.
p
m
= mass of particulate from filters, mg.
f
m
= mass of particulate from filter gaskets, mg.
g
m
= mass of particulate from the filter, filter gasket, and probe assembly from the room air
r
blank filter holder assembly, mg.
m
= Total amount of particulate matter collected, mg.
n
M
= the dilution tunnel dry gas molecular weight (may be assumed to be 29 g/g mole (lb/lb
s
mole).
P
= Barometric pressure at the sampling site, mm Hg (in. Hg).
bar
P
= Static Pressure in the tunnel (in. water).
g
P
= Percent of proportional sampling rate.
R
P
= Absolute average gas static pressure in dilution tunnel, mm Hg (in. Hg).
s
P
= Standard absolute pressure, 760 mm Hg (29.92 in. Hg).
std
Q
= Average gas flow rate in dilution tunnel.
std
Q
std
dscm/min (dscf/min).
T
= Absolute average dry gas meter temperature, K (R).
m
T
= Absolute average dry gas meter temperature during each 10-min interval, i, of the test
mi
run.
where:
T
= Absolute dry gas meter temperature at the beginning of each 10-min test interval, i, of
mi(b)
the test run, K (R), and
T
= Absolute dry gas meter temperature at the end of each 10-min test interval, i, of the
mi(e)
test run, K (R).
Ts
= Absolute average gas temperature in the dilution tunnel, K (R).
Tsi
= Absolute average gas temperature in the dilution tunnel during each 10-min interval, i,
of the test run, K (R).
where:
T
= Absolute gas temperature in the dilution tunnel at the beginning of each 10-min test
si(b)
interval, i, of the test run, K (R), and
T
= Absolute gas temperature in the dilution tunnel at the end of each 10-min test
si(e)
interval, i, of the test run, K (R).
Version: 05/10/17
Stove Builder International Inc. | 44826 | Rev: Aug 31 2018 3:17PM | Uncontrolled Copy
��
(
��
��
[
sec⁡
����
(
����
[
����
sec⁡
= 60 (1 - B
) V
A [T
P
/T
P
ws
s
std
s
s
std
T
= (T
+ T
)/2
mi
mi(b)
mi(e)
T
= (T
+ T
)/2
si
si(b)
m=si(e)
∎��������)(����⁡����)
1
]
2
(��)(����⁡����������)
−��������)(����⁡����)
1
]
2
(��)(����⁡����������)
]
Page 11 of 21
8431 Murphy Drive
Middleton, WI 53562
Telephone: 608-836-4400
Facsimile: 608-831-9279
www.intertek.com/building
GFT-OP-10c