Can Input Module (Scmi-600-02); Can Input Module (Scmi-600-02) - Parker Service Master CONNECT Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11.7

Can Input Module (SCMI-600-02)

Designation
Number
Plug
CANx-1xx
CANx-2xx
Interface
Protocols
Max. CAN Baud rate
Sensors, CAN1xx
Sensors, CAN2xx
Scanning rate, P-channel,
1
Housing material
Housing sealing
Type of protection
Ambient temperature
Storage temperature
The Parker Service Master CONNECT V1.2/06/21 EN
Properties
2
5-pin, M12×1, socket connector
120 Ω terminating resistor be-
tween PIN 4 and PIN 5, can be
switched off via software
120 Ω terminating resistor be-
tween PIN 4 and PIN 5, can be
switched off via software
Measuring bus based on RS-422
CANopen PDO, SAE-J1939,
CAN Generic
1000 kBit
Max. 24
Max. 24
1 ms = 1,000 measured values/s
ABS/PC
TPE
IP65
-10 – +50 °C
-20 – +60 °C
Technical Data
Description
CANx-1xx and CANx-2xx
SPEEDCON® connector
Galvanic separation (CAN High,
CAN Low and GND) to device
and CANx-2xx
Galvanic separation (CAN High,
CAN Low and GND) to device
and CANx-1xx
When installed
131

Publicité

Table des Matières
loading

Table des Matières