The file size expected and maximum storage time for the measurement
are calculated and displayed according to the applicable parameters
selected.
The table below contains information on the triggers available:
Designation
Keystroke
Level
Window
Time
External
Channel
warning value
Channel alarm
value
INFORMATION
Please note that the D-IN connection must be activated for the exter-
nal trigger. Refer to Chapter & "D-IN/D-OUT F1/F2" on Page 94.
The Parker Service Master CONNECT V1.2/06/21 EN
Description
Measurement is started by tapping on the corre-
sponding button
Measurement is started on exceeding or dropping
below a limit value
Measurement is started on exceeding or dropping
below one of two limit values for a defined
measuring range
Measurement is started at a defined moment of
time
Measurement is started on transition of a digital
signal from High to Low
Measurement is started on transition of a digital
signal from Low to High
Measurement is started when defined
warning values occurs
Measurement is started when defined
alarm values occur
Operation
79